silent-time

This command sets the amount of time the management console is
inaccessible after the number of unsuccessful logon attempts exceeds the
threshold set by the password-thresh command. Use the no form to
remove the silent time value.

Syntax

silent-time [seconds]
no silent-time

seconds - The number of seconds to disable console response.
(Range: 0-65535; 0: no silent-time)

Default Setting

The default value is no silent-time.

Command Mode

Line Configuration (console only)

Example
To set the silent time to 60 seconds, enter this command:

Related Commands

password-thresh (20-32)

databits

This command sets the number of data bits per character that are
interpreted and generated by the console port. Use the no form to restore
the default value.

Syntax

databits {7 | 8}
no databits

• 7 - Seven data bits per character.
• 8 - Eight data bits per character.

Console(config-line)#silent-time 60
Console(config-line)#