Lre upbo, Lre upbo -19 – SMC Networks TigerAccess SMC7816M User Manual

Page 701

Advertising
background image

L

ONG

-R

EACH

E

THERNET

C

OMMANDS

29-19

• The transceiver will adjust its transmitted signal to conform to the

power limitations set by the lre pbo-config command.

• If upstream power backoff is enabled with the lre upbo command

(page 29-19), the transceiver will automatically reduce the PSD at each
frequency breakpoint set the by the lre psd-breakpoints (page 29-12)
and lre psd-frequencies (page 29-13) commands.

Example
This example sets PSD values for downstream bands at 0 -60 -60 -60 0 0
dBm/Hz, and for upstream bands at 0 -11.2 -7.419 -7.419 0 0 dBm/Hz.

Related Commands

lre upbo (29-19)
show lre pbo-config (29-69)
lre psd-breakpoints (29-12)
lre psd-frequencies (29-13)

lre upbo

This command enables upstream power backoff. Use the no form to
restore the default setting.

Syntax

[no] lre upbo

Default Setting

disabled

Command Mode

Global Configuration
Interface Configuration (VDSL Port)

Console(config)#
Console(config)#lre pbo-config k1[0] 0 k1[1] -60000 k1[2] -60000

k1[3] -60000 k1[4] 0 k1[5] 0 k2[0] 0 k2[1] -11200 k2[2] -7419
k2[3] -7419 k2[4] 0 k2[5] 0

Console(config)#

Advertising