Clock timezone, Clock timezone -57, 57 clock timezone – SMC Networks TigerAccess SMC7816M User Manual

Page 517

Advertising
background image

T

IME

C

OMMANDS

20-57

clock timezone

This command sets the time zone for the switch’s internal clock.

Syntax

clock timezone name hour hours minute minutes {before-utc |
after-utc}

name - Name of timezone, usually an acronym. (Range: 1-29

characters)

hours - Number of hours before/after UTC. (Range: 0-13 hours)
minutes - Number of minutes before/after UTC. (Range: 0-59

minutes)

before-utc - Sets the local time zone before (east) of UTC.
after-utc - Sets the local time zone after (west) of UTC.

Default Setting

None

Command Mode

Global Configuration

Command Usage

This command sets the local time zone relative to the Coordinated
Universal Time (UTC, formerly Greenwich Mean Time or GMT),
based on the earth’s prime meridian, zero degrees longitude. To display
a time corresponding to your local time, you must indicate the number
of hours and minutes your time zone is east (before) or west (after) of
UTC.

Example

Related Commands

show sntp (20-56)

Console(config)#clock timezone Japan hours 8 minute 0 after-UTC
Console(config)#