Show lre line-profile, Show lre line-profile -77, Vdsl i – SMC Networks TigerAccess SMC7816M User Manual

Page 759

Advertising
background image

D

ISPLAYING

VDSL I

NFORMATION

29-77

Related Commands

lre apply (29-34)

show lre line-profile

This command displays a specified line profile which may be applied
selected VDSL ports.

Syntax

show lre line-profile [profile-name]

profile-name – Name of the profile. (Range: 1-31 alphanumeric
characters)

Command Mode

Privileged Exec

Command Usage

Use this command without a profile name to show the settings for all
configured line profiles, or with a profile name to display the settings
for a specific profile.

Example
This example shows the default settings for a line profile.

Console#show lre line-profile northport
northport:
down-fast-max-datarate :0
down-fast-min-datarate :0
down-max-inter-delay :4
down-min-noise-mgn :10
down-slow-max-datarate :200000
down-slow-min-datarate :64
down-target-noice-mgn :12
down-target-snr-mgn :24
snr-min-margin :20
up-fast-max-datarate :0
up-fast-min-datarate :0
up-max-inter-delay :4
up-min-noice-mgn :10
up-slow-max-datarate :200000
up-slow-min-datarate :64
up-target-noice-mgn :12
up-target-snr-mgn :32
Console#