Toshiba HWS-802XWHT6-E User Manual

Page 111

Advertising
background image

110

Toshiba

4. Auto Curve Setting

FC code setting can make flexible Auto-Curve settings.

<Preparation>

1

Press the TEST

and SET

and SELECT

buttons at the same time for 4 seconds or longer.
(See display

)

(Make sure that no operation is in progress.)

2

Specify an item code (FC) from among 29 to 2F with the
TEMP.

button for temperature setting.

3

Set data with the TIME

button for timer setting.

4

Press the SET

button. (If

lights, the status is

confirmed)

5

Repeat

2

through

4

for each item.

6

Pressing the TEST

button moves the unit to the normal

stop state.

• Auto-Curve temperature shift

Without Auto-Curve individually set, the set temperature can be
shifted in the range of ±5k of the current setting. (The set temperature
is valid only when Auto operation is in progress.)

1

Press the AUTO TEMP

button for 4 seconds or

longer. (See display

)

(The remote controller FC setting screen appears.)

2

Set a temperature shift range with the TEMP.

button for temperature setting. (-5k to 5k)

3

Press the SET

button. (If

lights, the status is

confirmed)

4

Pressing the TEST

button moves the unit to the normal

stop state.

FC

Item

Details

Fist shipment

29

Outside air temperature T1 temperature

-0015: -15°C

-

0000: 0°C

-0010: -10°C

2B

Outside air temperature T3 temperature

0000: 0°C

-

0015: 15°C

0010: 10°C

2C

Set temperature A with outside air temperature of -20°C

0020: 20°C

-

0055: 55°C

0040: 40°C

2D

Set temperature B with outside air temperature of T1

0020: 20°C

-

0055: 55°C

0035: 35°C

2E

Set temperature C with outside air temperature of 0°C

0020: 20°C

-

0055: 55°C

0030: 30°C

2F

Set temperature D with outside air temperature of T3

0020: 20°C

-

0055: 55°C

0025: 25°C

30

Set temperature E with outside air temperature of 20°C

0020: 20°C

-

0055: 55°C

0020: 20°C

31

Zone2 ratio with Zone1 as Auto

0000: 0%

-

0100: 100%

0080: 80%

2

3

6

4

1

E(20)

-20

T1

(-10)

0

T3

(+10)

20

Outside
air temperature (TO)

D(25)

C(30)

B(35)

A(40)

TSC-F
Set temperature ( )

Auto-Curve
Temperature shift

Default Setting

2

4

3

1

+00A09-002_01EN_SVM_ALL_Air_to_Water.book Page 110 Monday, October 5, 2009 2:09 PM

Advertising