Safety precautions, Danger, Warning – Toshiba HWS-802XWHT6-E User Manual

Page 4: Caution

Advertising
background image

3

Toshiba

1

SAFETY PRECAUTIONS

The unit and this service guide list very important safety precautions.
Understand the following details (indications and symbols) before reading the body text, and follow the instructions.

[About indication]

* Property damage indicates extended damage to property, furniture, livestock, or pets.

[About symbols]

Indication

Meaning of Indication

DANGER

Indicates that a wrong operation may cause a service engineer and the third persons
around to get fatal or serious injuries.

WARNING

Indicates that a wrong operation may cause a service engineer and the third persons
around to get fatal or serious injuries, or that unit defective after the operation may cause
a user to have a similar serious accident.

CAUTION

Indicates that a wrong operation may cause a service engineer and the third persons
around to get injuries or may cause property damage*, or that unit defective after the
operation may cause a user to have a similar accident.

Symbols

Meaning of Symbols

Indicates a forbidden action.

Specific forbidden actions are described in text near the symbol.

Indicates a forcible (must do) action.

Specific forcible actions are described in text near the symbol.

Indicates a caution (including danger and warning).

Specific cautions are described in picture or text inside or near the symbol.

DANGER

<Turn off the power breaker>

Turn off the power breaker before removing the front panel and cabinet.

• Failure to do so may cause a high voltage electric shock, leading to death or injury.
• During an operation, the second side circuit of high pressure transmission(*) are applied with a high voltage of 230V

or higher.

• Touching the circuit even with an electrical insulator, let alone a bare hand or body, causes an electric shock.

∗: For details, see the schematic.

<Discharge between terminals>

When the front panel and cabinet are removed, make short-circuit current to discharge between high pressure
capacitor terminals.

• Failure to do so may cause a high voltage electric shock, leading to death or injury.
• After the power is turned off, the high pressure capacitor is still charged with high voltage.

<Forbidden>

Do not turn on the power breaker after removing the front panel cabinet.

• Failure to do so may cause a high voltage electric shock, leading to death or injury.

WARNING

<Check earth ground>

Before starting failure diagnosis or repair, check that the ground wire (

∗) is connected to the unit ground terminal.

• An unconnected ground wire could cause an electric shock if electric leakage occurs.
• If the earth ground is not properly connected, ask an electrical worker for rework of the ground connection.

∗: Ground wire of class D grounding

+00A09-002_01EN_SVM_ALL_Air_to_Water.book Page 3 Monday, October 5, 2009 2:09 PM