139

Toshiba

4

Electric parts
replacement

2. Reactor

1) Perform the step 1-1.

2) Remove the relay connector connected to the

control board.

3) Cut the binding tie that binds the compressor leads

and relay connectors.

4) Remove the reactor.

(Truss B tight screw Ш4 Ч 6, 2 screws)

5) Attach a new reactor.

Note)

Be sure to bind the removed binding tie by using
the commercially available binding tie.
Make sure that the fan motor lead and the reactor
body do not contact each other.

No.

Exchange parts

name

Work procedure

Remarks

Relay connector

Reactor body

Fan motor lead

Control board

Binding tie
(Compressor lead, Relay connector)

+00A09-002_01EN_SVM_ALL_Air_to_Water.book Page 139 Monday, October 5, 2009 2:09 PM