[A12] Error Heating or Hot water supply heater failure

Water heat

exchanger board DPSW11-1,2

is ON

Replace booster heater
unit and safety valve

Set water heat board
DPSW11-1,2 to ON

A12 abnormality detection

No

(Backup heater NG)

Backup heater or

hot water cylinder terminal

has 230ACV ( ± 23V)

Power is connect

to backup heater or hot water

cylinder terminal

Yes

Yes

Restart

Operation starts under
10 TWI 20°C

Heater backup operation
Heating: Booster heater
Hot water supply: Hot water cylinder heater

After 1 hour since heater operation
started, neither TWI 15°C
nor TTW 20°C is met

Freeze prevention control is detected once

No

No

Place electric wire for
backup heater
Place electric wire for
hot water cylinder

Set breaker for backup
heater to ON
Set breaker for hot water
cylinder to ON
or check indoor wiring

No

Backup heater element

is conductive

Yes

Replace hot water
cylinder heater

No

(Hot water cylinder heater NG)

Hot water

cylinder heater element

is conductive

Yes

Replace TWI or TTW
sensor

No

(See characteristic table in page 101)

TWI, TTW sensor

characteristics are

normal

Yes

Yes

(Refer to hot water
cylinder guide)

Replace water heat

exchange control board

+00A09-002_01EN_SVM_ALL_Air_to_Water.book Page 83 Monday, October 5, 2009 2:09 PM