8-3.

Hydro Unit
Control

5) Mixing Valve control (2-temperature heating control)
To set different radiator unit supply temperatures or floor heating supply temperatures, the unit performs Mixing Valve
control.
When Mixing Valve "Yes" is selected, the unit controls Mixing Valve every 4 minutes (FC) based on the difference TSC_

Δ

T between the Zone2 set temperature and TFI (floor inlet water temperature sensor) temperature as follows:

For 2-temperature control, DP_SW12-3 Zone2 "Yes" must be selected.

Related FC

6) Q-H characteristics of hydro unit

The following shows the Q-H characteristics.

6-1) HWS-801XWHM3-E, T6-E

6-2) HWS-1402XWHM3-E, T6-E, T9-E

Item

Operation flow and applicable data, etc.

TSC_

ΔT

2

TSC_

ΔT

-2

TSC_

ΔT < 2

-2 > TSC_

ΔT

Control value

+ 1 step (Open)

± 0 step

- 1 step (Close)

Initial value

Driving range

1 step

Control cycle

6

0-12

3 WV move 7.5 degs

4 mins (FC)

FC No.

Setting item

Default

Setting available range

0C

Mixing Valve operation time

60

30 - 240 secs

59

Mixing Valve control time

4

1 - 30 mins

Flow rate(L/min)

Pump head(m)

0

10

15

20

25

30

1

2

3

4

5

6

7

8

Out of
Operation
Range

SW1

SW2

SW3

Minimum flow rate

Hydraulic heat exchanger(8kW)QH characteristics

0

0

5

10

15

20

Flow rate(L/min)

25

30

35

40

45

50

55

60

65

1

2

3

4

Pump head(m)

5

6

7

8

9

Minimum flow rate

Hydraulic heat exchanger(14kW)QH characteristics

10

Out of Operation
Range

SW1

SW2

SW3

+00A09-002_01EN_SVM_ALL_Air_to_Water.book Page 53 Monday, October 5, 2009 2:09 PM