Toshiba HWS-802XWHT6-E User Manual

Page 150

Advertising
background image

149

Toshiba

4

Electric parts
replacement

2. Reactor

1) Perform the step 1-1.

2) Remove the reactor lead connected to the control

board.
CN05 White, CN06 White

3) Cut the binding tie that binds the compressor leads

and fan motor leads.

4) Remove the reactor.

(Truss B tight screw Ш4 Ч 6, 2 screw)

5) Attach a new reactor.

Note)

Be sure to bind the removed binding tie by using
the commercially available binding tie.
Make sure that the fan motor lead and the reactor
body do not contact each other.

No.

Exchange parts

name

Work procedure

Remarks

Reactor lead

Reactor lead

Reactor body

Fan motor lead

Binding tie
(Compressor lead,
Reactor lead)

Binding tie
(Compressor lead,
Reactor lead)

Binding tie
(Fan motor lead,
Reactor lead)

Control board

+00A09-002_01EN_SVM_ALL_Air_to_Water.book Page 149 Monday, October 5, 2009 2:09 PM