Toshiba HWS-802XWHT6-E User Manual

Page 135

Advertising
background image

134

Toshiba

15

Heater assembly

1. How to remove

1) Perform the step 1-1, step 5, 6, 7, and 11.
2) Remove the nut of the heater connection.
3) Remove the 2 fixed screws of the heater.
4) Pull the heater out upward.
5) Remove the insulator from the heater.

2. How to attach

1) Attach a new heater in the reverse order of the

removal.

16

TC sensor
TWI sensor
TWO sensor
THO sensor

1. How to remove

1) Perform the step 1-1 and step 5.
2) Take the sensor out.

No.

Exchange parts name

Work procedure

Remarks

To replace a water circuit part, first close the water
supply source valve and the valve of water pipe
connected to the hydro unit.

The heater connection uses a liquid packing for
water seal. When replacing the heater, use a
packing which was slathered with the liquid gasket.

Part code

Service parts

37595721

Packing

37595722

Liquid gasket

After the heater assembly replacement repair, open
the water supply source valve and water piping
valve to pass water through the hydro unit, and
check that the heater connection has no water
leakage.

Nut

Heater
assembly

Insulator

Heater
assembly

THO sensor
Sensor diameter: 6
Tube color: Gray

TC sensor
Sensor diameter: 6
Tube color: Black

TWI sensor
Sensor diameter: 4
Tube color: Blue

TWO sensor
Sensor diameter: 6
Tube color: Red

+00A09-002_01EN_SVM_ALL_Air_to_Water.book Page 134 Monday, October 5, 2009 2:09 PM

Advertising