122

Toshiba

(2) LED indication switching (SW800, SW803 operation)

(2) -1. Indication switching list

Operating SW803 can switch the indications of LED D800 to D804 on the outdoor control board.

Switch

Function and details

Abnormality indication (Current abnormality)
This switch indicates the current abnormality.
Without an abnormality, the lights are off.

(See (2)-2)

Abnormal indication (Latest abnormality: Latest abnormality including the current one)
After the abnormality status is released, this setting enables users to see the previous abnormalities.
(Previous abnormality can be checked even if the power is once turned off.)
* If there is an abnormality now, the abnormality details of the current one is displayed.
* This setting does not display a TO sensor failure.

(Check for the failure with the setting for current abnormality.)

(See (2)-2)

Temperature sensor indication
These switches indicate the temperature sensor detecting value.
* TC=TWO+2 (heating, hot water supply)

TC=TWO (cooling)

(See (2)-3)

Current indication
This switch indicates the current value in the outdoor unit.

(See (2)-3)

Compressor operation frequency indication
This switch indicates the compressor operation frequency.

(See (2)-3)

PMV Openness indication
This switch indicates PMV (Pulse motor valve) position.

(See (2)-3)

1234

ON

SW803

1234

ON

SW803

1234

ON

TD

SW803

1234

ON

TE

SW803

1234

ON

TS

SW803

1234

ON

TO

SW803

1234

ON

TL

SW803

1234

ON

TH

SW803

1234

ON

TWI

SW803

1234

ON

TC*

SW803

1234

ON

SW803

1234

ON

SW803

1234

ON

SW803

+00A09-002_01EN_SVM_ALL_Air_to_Water.book Page 122 Monday, October 5, 2009 2:09 PM