Toshiba HWS-802XWHT6-E User Manual

Page 117

Advertising
background image

116

Toshiba

10. Hot Water Boost Setting

This setting heats the water whenever necessary by using the heat pump and hot water cylinder heater.

1

Press the HOT WATER

button to start a hot water

supply operation.

(Normal hot water supply operation)

2

Pressing the HOT WATER BOOST

button displays the

symbol. (See display

)

(The set temperature does not change) The hot water supply operation
of 75°C starts.

HOT WATER BOOST operation with the heat pump and heater ends when
the water temperature reaches 75°C; however, the normal hot water supply
operation automatically starts after 60 minutes even if the temperature is
not as high as 75°C.

3

Pressing the HOT WATER BOOST

button again makes

disappear, and the HOT WATER BOOST ends.

<How to set HOT WATER BOOST operation time and temperature>

In FC_08 or 09 (See 2-2), the operation time and set temperature can be changed.
FC_08: Operation time change range 30 to 120 minutes (60 minutes: default)
FC_09: Set temperature change range 40 to 80°C (75°C: default)

11. Nighttime Low-noise Setting

• This setting is used to reduce noise output, from the outdoor unit, during

nighttime for neighbours. Nighttime low-noise operates with lower
operation frequency and fan tap than usual only for the set time period.

• The operation is the same as usual hot water supply, heating, or cooling.
• Adjust the unit time before making the settings.

<How to enable, set start time and end time of nighttime low-
noise>

1

Press the TEST

and TEMP.

button at the same

time for 4 seconds or longer. (See display

)

(Moves to the nighttime low-noise setting mode)
"09" displayed in the Code No. field and the DATA currently
displayed,

, and

blink.

2

Press TIME

to set enabled "1" or disabled "0".

Pressing SET

changes DATA and

indication to be lit and the setting is confirmed. (For DATA, only

1 or 0 can be selected.)

3

Press the TEMP.

button to change Code No. to "0A". DATA and

indication again

blink.

4

Press the TIME

button to set start time. Pressing SET

changes DATA and

indication to be lit and the setting is confirmed.

5

Press the TEMP.

button to change Code No. to "0B". DATA and

indication again

blink.

6

Press the TIME

button to set end time. Pressing SET

changes DATA and

indication to be lit and the setting is confirmed.

7

Press TEST

to exit the nighttime low-noise time setting mode.

and

indications go

out.

2,3 1

2,
4,
6

3,
5

1

4,6

7

+00A09-002_01EN_SVM_ALL_Air_to_Water.book Page 116 Monday, October 5, 2009 2:09 PM

Advertising