Operation flow and applicable data, etc.

Operation description

8-1.

Basic
Operation

1) Operation control

Remote controller

1. Purpose

The operations of the
hydro unit and the
outdoor unit are
controlled according to
user-defined operation
condition settings.

2. Details

The operation controls
include those shown in
the left.

3. Operations

1) An operation condition

is selected with the
remote controller.

2) Setting the remote

controller button to
“ON” transmits a signal
to the hydro unit.

3) The hydro unit

controller controls the
operations shown in
the left while also
controlling the water 2-
way valve, water 3-way
valve, circulation
pump, mixing valve,
hot water cylinder
heater, and backup
heater.

4) The hydro unit

controller transmits an
operation instruction to
the outdoor unit, and
uses serial signals to
transmit and receive
control statuses.

5) The outdoor unit

control unit performs
the operation controls
shown in the left while
also controlling the
compressor, outdoor
fan motor, pulse motor
valve, and 4-way valve.

Operation
condition selection

Serial signals

transmit and receive

Heating: Run/Stop

Hot water supply: Run/Stop

Cooling: Run/Stop

Serial signals transmit

and receive

Serial signals

transmit and receive

Remote control settings
<Heating> Temperature setting
<Hot water supply > Temperature setting
<Cooling> Temperature setting

Auto Temp
Anti Bacteria
Frost protection
Hot waterboost

Water heat
exchange
Sub board

Outdoor

unit control

Serial signals

transmit and receive

Outdoor unit contro
Inverter frequency control
Waveform synthesis function

Calculation function (Temperature calculation)

AD conversion function
Rapid heating function
Compressor restart
Delay function
G-Tr overcurrent prevention function
Defrosting operation function

Hydro
unit

Outdoor
unit

Compressor
Outdoor fan motor

Td sensor
Ts sensor
Te sensor
To sensor
PMV
4-way valve

Thermostat (Cooling/Heating)

Forcible stop input

Abnormal stop output
Defrosting output
Operation output
Boiler "ON/OFF"
Booster Heater

Water heat
exchange
control board

Inverter

Condensed temperature sensor (TC)
Water inlet temperature sensor (TWI)
Water outlet temperature sensor (TWO)
Water heater outlet temperature sensor (THO)
Hot water cylinder (TTW)
Floor inlet sensor (TFI)
Overheat prevention thermostat
Flow switch
Hot water cylinder heater
Backup heater 1 power-relay
Backup heater 2 power-relay

AC pump 1 (Built-in pump)

2WV_W
3WV_W

Mixing Valve

Pressure switch

Lo pressure sensor

AC 230 V for Hot water cylinder heater

AC 230 V for heat pump

AC 400 V (3N~) for Back up heater

Serial
communication

Hot water supply
heater MG