Key electric component rating, 1. hydro unit – Toshiba HWS-802XWHT6-E User Manual

Page 25

Advertising
background image

24

Toshiba

6

Key Electric Component Rating

6-1. Hydro Unit

HWS-802XWHM3-E, 802XWHT6-E

O ········· Applied
OP······· Optional accessory

No.

Component name

Model name

Type name

Rating

M3-E

T6-E

1

Circulating pump

O

O

UPS025-65 K 130

AC230 V 0.54 A (MAX)

2

Backup heater 6 kW

O

O

AC 400 V (3N) 6 kW (AC230 V 3 kW

compatible)

3

Backup heater 9 kW

AC400V (3N) 9 kW

4

Water heat exchange

temperature sensor

(TC sensor)

O

O

10 k

Ω (25°C)

5

Water inlet temperature sensor

(TWI sensor)

O

O

10 k

Ω (25°C)

6

Water outlet temperature sensor

(TWO sensor)

O

O

10 k

Ω (25°C)

7

Heater outlet water temperature

sensor

(THO sensor)

O

O

10 k

Ω (25°C)

8

Floor inlet temperature sensor

(TFI sensor)

O

O

10 k

Ω (25°C)

9

Pressure switch

O

O

Operating pressure 4.15 MPa +0 -0.3 MPa

10

Low pressure sensor

O

O

Operating pressure 0.20 MPa

11

Bimetal thermostat (auto)

O

O

Operating temperature 75±3°C DC42 V / 0.2 A

12

Bimetal thermostat (single

operation)

O

O

Operating temperature 95±5°C AC250 V / 16 A

13

Flow switch

O

O

Operating flowing quantity 13 L/min

14

Output board (OP)

OP

OP

TCB-PCIN3E

AC230 V 0.5 A DC24 V 1 A

15

Input board (OP)

OP

OP

TCB-PCM03E

Contact input

16

Remote control

O

O

HWS-AMS11E

17

Water 3-way valve terminal

O

O

AC230 V 0.1 A

2Wire, 3Wire SPST, SPDT type mountable

18

Water 2-way valve terminal

O

O

AC230 V 0.1 A 2Wire type mountable

19

Mixing valve terminal

O

O

AC230 V 0.1 A

3Wire SPST, SPDT type mountable

20

Circulating pump terminal

O

O

AC230 V 1.0 A

21

Booster heater terminal

O

O

AC230 V 1.0 A

22

Fuse

O

O

AC 250 V 30 A

+00A09-002_01EN_SVM_ALL_Air_to_Water.book Page 24 Monday, October 5, 2009 2:09 PM

Advertising