Toshiba HWS-802XWHT6-E User Manual

Page 50

Advertising
background image

49

Toshiba

8-3.

Hydro Unit
Control

1-2) High temperature release control

A heat pump operation is performed as shown in the table below according to the TC sensor detecting temperature.
• For the detected temperature, TC (= TWO + 2 degree) of a heat pump operation is used. The values of T7 through

T10 vary depending on TWI. (See the table below)

• If the compressor frequency instruction from the hydro unit is less then 10 Hz, the compressor stops.
• TC > 62°C causes the compressor to stop abnormally. When the compressor restarts 140 seconds after the stop

and TC > 62°C is not detected for 20 minutes, the abnormal stop counter is cleared. 10 times of compressor
abnormal stop stops the operation of heat pump, and confirms the abnormality (Display: A11).

* If the heat pump operation is switched to other operation, the abnormality detection counter is reset to 0.

TC=TWO+2deg

(°C)

1-3) Low temperature release control

A heat pump operation is performed as shown in the table below according to the TC sensor detecting temperature.
• For the detected temperature, TC = TWO of a heat pump operation is used. The values of T7 through T10 varies

depending on TWI. (See the table below)

• If the compressor frequency instruction from the hydro unit is less then 10 Hz, the compressor stops.
• TC < 3°C causes the compressor to stop abnormally. When the compressor restarts when 140 seconds has

passed after the stop and TC < 3°C is not detected for 20 minutes, the abnormal stop counter is cleared. 10 times
of compressor abnormal stop stops the operation of heat pump, and confirms the abnormality (Display: A11).

* If the heat pump operation is switched to other operation, the abnormality detection counter is reset to 0.

TC=TWO

(°C)

Item

Operation flow and applicable data, etc.

T11

(62.0°C)

TC (TWO+2)

Forcible stop

O (down)

P (slow down)

Q (keep)

R2 (slow up)

R1
(slow up)

S (normal)

T9

T10

T8

T7

Zone

Control operation

R1

Increase compressor frequency by 1.2 Hz every
60 secs.

R2

Increase compressor frequency by 0.6 Hz every
60 secs.

O

Decrease compressor frequency to 70% every
10 secs.

P

Decrease compressor frequency by 3 Hz every
10 secs.

Q

Keep compressor frequency.

TWI

T7

T8

T9

T10

T11

TWI<30

57.0

59.0

60.0

61.0

62.0

30

TWI<35

57.0

59.0

60.0

61.0

62.0

35

TWI<40

56.5

58.5

59.5

60.5

62.0

40

TWI<45

56.5

58.5

59.5

60.5

62.0

45

TWI<50

56.0

58.0

59.0

60.0

62.0

50

TWI

56.0

58.0

59.0

60.0

62.0

T7

Forcible stop

O (down)

P (slow down)

Q (keep)

R2 (slow up)

R1
(slow up)

S (normal)

T9

T8

T10

T11

TC (TWO)

Zone

Control operation

R1

Increase compressor frequency by 1.2 Hz every
60 secs.

R2

Increase compressor frequency by 0.6 Hz every
60 secs.

O

Decrease compressor frequency to 70% every
10 secs.

P

Decrease compressor frequency by 3 Hz every
10 secs.

Q

Keep compressor frequency.

TWI

T7

T8

T9

T10

T11

TWI<10

10.0

8.0

6.0

4.0

3.0

10

TWI<15

10.5

8.5

6.5

4.5

3.0

15

TWI<20

11.0

9.0

7.0

5.0

3.0

20

TWI

11.5

9.5

7.5

5.5

3.0

+00A09-002_01EN_SVM_ALL_Air_to_Water.book Page 49 Monday, October 5, 2009 2:09 PM