8-1.

Basic
Operation

4) Cooling operation

NOTE:

No coding mode in default setting. When use the cooling mode, please change the
FC02 to “0”.

Related FC

1. Purpose

Cooling

2. Details

This section performs
cooling operation
according to cooling
conditions specified for
the steps in the left.

3. Operations

1) Set the [ZONE1, 2]

remote controller
button to “ON”.

2) The hydro unit

controller starts to
transmit a cooling
operation signal to the
outdoor unit control
unit.

3) The hydro unit

controller performs the
operation controls
shown in the left while
also controlling the
circulation pump, water
2-way valve, and water
3-way valve.

4) The outdoor unit

controls the
compressor, outdoor
fan motor, pulse motor
valve, and 4-way valve
based on the operation
signals transmitted by
the hydro unit.

Item

Operation flow and applicable data, etc.

Operation description

Hydro unit

control

ZONE1, 2

button set to "ON"

Circulation pump "ON/OFF" control
Water 3-way valve control
Water 2-way valve control

Cooling temperature: 10°C to 25°C

Number of compressor revolutions control
Number of outdoor fan motor revolutions control
Pulse motor valve control
4-way valve control

Outdoor unit

control

Operation instruction

signal transmit

FC No.

Setting item

Default

Setting available range

02

Cooling mode availability

1: No

0: Yes

+00A09-002_01EN_SVM_ALL_Air_to_Water.book Page 38 Monday, October 5, 2009 2:09 PM