[A07] Error Pressure switch operation (Hot water supply/Heating operation)

Replace flow switch

Remove waste

Flow switch is normal

Secure water
circulation amount

Circulation flow
shortage

Waste stuck inside
water circuit

12 M or longer water
pipe to a branch,
or 5 or less branches

Remove sufficiently
excess air

Place buffer tank and
the second pump

No

Excess air

noise comes from

inside pump

Chattering

noise comes from

flow switch

Start

No

No

Yes

Lower set temperature

Yes

Continued

operation at high outside air

temperature and at 50°C or higher

set temperature

No

Attach TWO sensor

No

TWO sensor

is attached

to pipe.

Yes

Replace pressure switch

No

Pressure switch

is normal

Yes

Yes

Yes

Replace water heat

exchange control board