[A04] Error Freeze prevention control

When the outside temperature or inlet water temperature is low (approx. 20°C or lower) and the room load is large
(operation frequency rating), the freeze prevention control may be activated.

Excess air

inside pump

Secure water
circulation amount

Circulation
flow shortage

Dirt clogging
inside water circuit

12 M or longer
water pipe to
a branch, or 5 or
less branches

Fit buffer tank and the
second pump

Set DP_SW11-1 to ON

No

No

No

No

(inside strainer, etc)

Chattering from

flow switch

Water heat

exchanger board DP_SW11-1

is ON

Power is

connect to backup

heater terminal

Backup

heater terminal has

230ACV ( ± 23V)

Start

Operation restart

Replace water heat

exchange control board

Perform

air vent

Set heater breaker to ON
Check indoor wiring

Replace flow switch

No

Yes

Yes

Yes

Yes

Replace backup heater unit

No

(Backup heater NG)

(See Characteristic table on page 101)

Backup

heater element

is conductive

Yes

Replace TC, TWO,
and TWI sensors

No

TC, TWO, TWI

sensor characteristics

are correct

Yes

Connect backup heater
power cable

Yes