Chapter 6. Troubleshooting

List of Alarms

Alarms are reported on the receiver display screen. A blinking
warning sign appears on the status screen prompting you to
press the Scroll button so you can read the alarm label.

To acknowledge an alarm message once the alarm label is
displayed on the screen, press the Scroll button again. If
several alarm messages are reported, press the Scroll button
as many times. This will acknowledge each message, one
after the other.

If the reason for raising an alarm persists, you won’t be able
to acknowledge the alarm until you correct the problem.

Some of the alarms listed below can only be the result of a
bad serial command submitted to the receiver (in command
mode). Serial commands can be applied to the receiver in
different ways, from the field terminal running your field
software, or from a PC’s terminal window (through a serial
connection).

#

Rank

Alarm Label

Symptoms & Remedies

0

Medium Software error

Receiver detected an internal error due to software. If persisting, 2nd-
level maintenance is required for the receiver.

1

Medium Unknown command

Unknown serial command received. Correct syntax and re-send com-
mand.

2

Medium Bad parameter

Not well-formatted parameter in the command sent. Correct syntax
and re-send command.

3

Medium Bad command checksum

Serial command received with bad checksum. Correct checksum and
re-send command.

4

Medium File open error

Receiver failed to open the raw data file. Restart the receiver an try
again.
If error persists and selected storage medium is USB, change USB key
and try again.
If error persists and selected storage medium is internal memory, re-
format internal memory using command $PASHS,INI,2 (configuration
will be lost).