Som,ctt: cumulative tracking time mask, Function, Command format – Spectra Precision ProMark 800 Reference Manual User Manual

Page 254

Advertising
background image

242

Set Command Library

SOM,CTT: Cumulative Tracking Time Mask

Function

This command is used to mask the signal observations that
do not meet the minimum continuous tracking time you
specify. This means that only the observations meeting this
requirement will be output (all the others will be rejected).

This mask is enabled only after the “User-defined” option (9)
has been selected with the $PASHS,SOM command.

Command Format

Syntax

$PASHS,SOM,CTT,d1[,d2][*cc]

Parameters

Comments

• “Continuous” tracking means tracking “without cycle

slips”.

• This command can only mask some particular signal data.

If however at the same time the L1CA data are disabled,
then ALL the satellite observations, and not only the
masked ones, will be rejected.

• This command equally affects all GNSS and their signals.

Examples

Setting CTT masks for differential and raw data to 20 s:

$PASHS,SOM,CTT,20*65

Enabling all signal observations to be output regardless of the
continuous tracking time requirement (no CTT mask):

$PASHS,SOM,CTT,0*57

Parameter

Description

Range Default

d1

Minimum continuous tracking time for differen-
tial data, in seconds. “0” means no mask.

0-255

10

d2

Minimum continuous tracking time for raw data,
in seconds. If d2 is omitted, then the receiver
will assume d2=d1. “0” means no mask.

0-255

10

*cc

Optional checksum

*00-*FF

Raw Data Masked by d2

Differential Data Masked by d1

MPC
DPC
ATM,MESATM,RNX,SCN,0

All other messages