Atm: atom data parameters, Function, Command format – Spectra Precision ProMark 800 Reference Manual User Manual

Page 279: Response format

Advertising
background image

267

Query Command Library

ATM: ATOM Data Parameters

Function

This command allows you to read the current settings of the
ATOM data-related parameters.

Command Format

Syntax

$PASHQ,ATM[*cc]

Response format

Syntax

(Through an example)

$PASHQ,ATM

PER:001.00 ELM:5
DRI:001.00 SIT:2007 REC:N MEM:M
ANH:02.132 ANT:VERT ANR:ON
ATOM: MES PVT ATR NAV DAT EVT BAUD
PRTA: OFF OFF OFF OFF OFF OFF 7
PRTC: OFF OFF OFF OFF OFF OFF 1
PRTE: OFF OFF OFF OFF OFF OFF 1
MEMM: OFF OFF OFF OFF OFF OFF 1
MEMU: OFF OFF OFF OFF OFF OFF 0

Parameters

Parameter

Description

Range

PER

ATOM output rate

0.00-999.0 s

ELM

Elevation mask used in data recording &
data output

0-90

DRI

Recording rate

0.00-999.0 s

SIT

Site ID

4 characters

REC

Data recording:
• Y: Data recording enabled
• N: Data recording disabled
• S: Data recording enabled but stopped

Y, N, S

MEM

Selected memory:
• M: Internal memory
• U: USB memory

M, U

ANH

Antenna height

0.000-99.999

ANT

Height measurement type (slant/vertical)

SLANT, VERT

ANR

Antenna reduction mode

ON, OFF, ARP

PRTA

ON, OFF

PRTC

Label for Bluetooth

ON, OFF

PRTE

Label for Modem

ON, OFF

MEMM
MEMU

Labels for memories

ON, OFF

Advertising