Udp: user-defined dynamic model parameters, Unt: distance unit used on display screen – Spectra Precision ProMark 800 Reference Manual User Manual

Page 261

Advertising
background image

249

Set Command Library

UDP: User-Defined Dynamic Model Parameters

Function

This command is used to set the upper limits of the dynamic
model (velocity, acceleration).

Command Format

Syntax

$PASHS,UDP,f1,f2,f3,f4[*cc]

Parameters

Example

Setting the dynamic model:

$PASHS,UDP,10,1,2,0.5*1D

Comments

The user-defined dynamic model is activated by the
$PASHS,DYN,9 command. Note that when the adaptive
dynamic mode (DYN,8) is selected, the user-defined model is
automatically excluded from the possible models that could
best describe the current receiver dynamics.

Relevant Query

Command

$PASHQ,UDP

See Also

$PASHS,DYN

UNT: Distance Unit Used on Display Screen

Function:

This function is used to choose the distance unit you want the
receiver to use when providing coordinates on its display
screen.

Parameter

Description

Range

Default

f1

Maximum expected horizontal velocity in
m/s.

0-100 000 100 000

f2

Maximum expected horizontal accelera-
tion in m/s/s.

0-100

100

f3

Maximum expected vertical velocity in m/
s.

0-100 000 100 000

f4

Maximum expected vertical acceleration
in m/s/s.

0-100

100

*cc

Optional checksum

*00-*FF

-

Advertising