Query Command Library

Parameters

Example

$PASHQ,UDP
$PASHR,UDP,100000.00,100.00,100000.00,100.00*35

Relevant Set

Command

$PASHS,UDP

See Also

$PASHS,DYN

UNT: Distance Unit Used on Display Screen

Function

This command allows you to know which distance unit is
currently used on the receiver display screen to express the
coordinates of the computed position.

Command Format

Syntax

$PASHQ,UNT[*cc]

Response Format

Syntax

$PASHR,UNT,s*cc

Parameter

Description

Range

Default

f1

Maximum expected horizontal veloc-
ity, in m/s

0-100 000

100 000

f2

Maximum expected horizontal accel-
eration, in m/s²

0-100

100

f3

Maximum expected vertical velocity,
in m/s

0-100 000

100 000

f4

Maximum expected vertical accelera-
tion, in m/s²

0-100

100

*cc

Checksum

*00-*FF