Rst: default settings – Spectra Precision ProMark 800 Reference Manual User Manual

Page 247

Advertising
background image

235

Set Command Library

Example

Choosing scenario 4 with 1 sec and 30 sec for the output
rates:

$PASHS,RNX,TYP,4,1,30*6A

Relevant Query

Command

$PASHQ,RNX,MSI

See Also

$PASHS,BAS

$PASHS,CPD,MOD,BAS

RST: Default Settings

Function

This command is used to reset the receiver parameters to
their default values.

Command Format

Syntax

$PASHS,RST[*cc]

Parameters

None.

Example

Resetting the receiver:

$PASHS,RST*20

101

L1&L2 compact pseudo-range and compact carrier phase, extended
fixed position follows every 12 epochs, all the data are decimated in 5
times compared to L1 carrier phase. This scenario cannot be used
with a moving receiver
.

201

Same as scenario 1, but extended computed reference position fol-
lows each epoch.

202

Same as scenario 2, but extended computed reference position fol-
lows each epoch.

203

Same as scenario 3, but extended computed reference position fol-
lows each epoch.

204

Same as scenario 4, but extended computed reference position fol-
lows each epoch.

300

Same as scenario 100, but extended computed reference position fol-
lows each epoch.

Scenario

Number

Description

Advertising