Qzs: qzss tracking status, Relevant set command, Function – Spectra Precision ProMark 800 Reference Manual User Manual

Page 355: Command format

Advertising
background image

343

Query Command Library

Parameters

Comments

With no internal battery in, fields f4, d5 and d7 are all empty.
With no external power source applied, field f6 is empty.

Example

$PASHQ,PWR
$PASHR,PWR,6.8,9.1,2,,,11.6,,44*0D

Relevant Set

Command

$PASHS,PWR,PAR

QZS: QZSS Tracking Status

Function

This command is used to read the current status of QZSS
tracking.

Command Format

Syntax

$PASHQ,QZS[*cc]

Parameters

None.

Parameter

Description

Range

f1

Battery voltage threshold, in volts, triggering a low-bat-
tery alarm

6.7-8.4

f2

External power voltage threshold, in volts, triggering a
low-power alarm

9.0-28

d3

Power source:
• 0: Internal battery
• 1: External battery
• 2: External DC source

0-2

f4

Battery DC output voltage, in volts

0.0-12.0

d5

Percentage of remaining battery energy

0-100

f6

DC input voltage from external power, in volts

0.0-30.0

d7

Battery charging status:
• 0: Charging
• 1: Discharging
• 2: Fully charged

0-2

d8

Internal temperature, in °Celsius

*cc

Checksum

*00-*FF

Advertising