Troubleshooting

• Connect a USB stick to the receiver through the USB

device cable provided and press the Log button again.

• Restore the default settings (by pressing the

Log+Scroll+Power buttons simultaneously) in order to
make the internal memory the active memory. Press
the Log button again.

If neither of these two actions resolves your problem, go to
step 3.

Step 3. Is the

Currently Used

Memory Full?

Data logging will stop automatically or won’t start if the
storage medium used (internal memory or USB stick) is full.
On the General Status screen, read the remaining percentage
of free memory (second line, last number in the line).

1. If “0%” is displayed, then the memory used is full. Do one

of the following:

Change the storage medium

Using your field terminal, empty the memory or delete
the files you don’t need anymore.

If neither of these two actions resolves your problem, you
may have a malfunctioning receiver. Contact your local
dealer or email Technical Support for assistance.

2. If the memory is not full (>0%), you may have a

malfunctioning receiver. Contact your local dealer or email
Technical Support for assistance.

Radio Data Link Fails to Provide Base Corrections to Rover

The Data Link icon is displayed on the rover’s General Status
screen when base corrections are received and a float or fixed
solution is available. Next to it is the age of corrections, a
value which should not normally exceed a few seconds when
the data link operates smoothly.

After examining the General Status screen, you determine
that the rover is not receiving data. Follow the outline below
to troubleshoot this problem.

RTK Base

RTK Rover

PP Base

PP Rover