Set Command Library

ATM,PER: Setting Unique Output Rate for all ATOM Messages

Function

This command is used to set the same output rate for all
ATOM messages. This command will overwrite all the output
rates set individually for each message type using
$PASHS,ATM,RNX and $PASHS,ATM,PVT.

Command Format

Syntax

$PASHS,ATM,PER,f[*cc]

Parameters

Example

Setting the output rate to 1 second:

$PASHS,ATM,PER,1*5B

Relevant Query

Command

$PASHQ,ATM

See also

$PASHS,ATM

ATM,VER: Setting the Version of ATOM Messages

Function

This command is used to set the version in which the receiver
will generate ATOM messages on all its ports.

Command Format

Syntax

$PASHS,ATM,VER,d[*cc]

Parameter

Description

Range

f

Output rate.
Setting $PASHS,POP to “20” is a
prior condition to operating at
0.05 s (20 Hz).

0.05 sec or 0.1-0.4 sec if the
[F] option is activated
0.5-0.9 sec
1-999 sec

*cc

Optional checksum

*00-*FF