Set Command Library

Command Format

Syntax

$PASHS,DIP,PAR,ADD,s1,PRT,d2[,LGN,s3,PWD,s4][*cc]

Parameters

Comments

When connecting to the specified server requires a user name
and password, then the receiver will send the serial command
$GPUID,s3,s4 after the IP connection with the server has
been established.

Examples

Entering the parameters of the server the receiver has to
connect to (through an IP address):

$PASHS,DIP,PAR,ADD,192.65.54.1,PRT,2100*74

Entering the parameters of the server the receiver has to
connect to (through a host name):

$PASHS,DIP,PAR,ADD,www.MyRec.com,PRT,2100*05

Relevant Query

Commands

$PASHQ,DIP

$PASHQ,MDM

See Also

$PASHS,DIP,ON

$PASHS,DIP,OFF

$PASHS,MDM

DRD: Data Recording Duration

Function

This command sets a duration for all the G-files that the
receiver will log (outside of sessions). When a duration is set,
the receiver automatically creates a new G-file right after the
currently logged G-file has reached the specified duration.

Parameter

Description

Range

Default

ADD,s1

IP address or host name of
external server

32 characters max.

PRT,d2

IP port of external server

0-65535

LGN,s3

User name (optional)

32 characters max.

PWD,s4

Password (optional)

32 characters max.

*cc

Optional checksum

*00-*FF