Vec: vector & accuracy data, Function, Command format – Spectra Precision ProMark 800 Reference Manual User Manual

Page 394: Response format

Advertising
background image

382

Query Command Library

VEC: Vector & Accuracy Data

Function

This command is used to query the receiver for vector and
accuracy data.

Command Format

Syntax

$PASHQ,VEC[*cc]

Response Format

Syntax

$PASHR,VEC,c1,d2,m3,f4,f5,f6,f7,f8,f9,f10,f11,f12,d13*cc

Parameters

Example

$PASHQ,VEC
$PASHR,VEC,3,09,130924.00,-37.683,55.081,-17.925,0.016,0.012,0.026,
0.234765,0.098765,0.098763,0001*71

Parameter

Description

Range

c1

Position mode:
• 0: Autonomous
• 1: RTCM (or SBAS Differential)
• 2: RTK float
• 3: RTK fixed
• 9: SBAS Differential. See comment.

0-3, 9

d2

Number of SVs used in position compu-
tation

3-27

m3

UTC time (hhmmss.ss)

000000.00-235959.99

f4

X component of vector (along ECEF X
axis), in meters

±99999.999

f5

Y component of vector (along ECEF Y
axis), in meters

±99999.999

f6

Z component of vector (along ECEF Z
axis), in meters

±9999.999

f7

X component standard deviation

99.999

f8

Y component standard deviation

99.999

f9

Z component standard deviation

99.999

f10

XY correlation

±9.999999

f11

XZ correlation

±9.999999

f12

YZ correlation

±9.999999

d13

Base station ID (RTCM only)

0-4095

*cc

Checksum

*00-*FF

Advertising