Spectra Precision ProMark 800 Reference Manual User Manual

Page 372

Advertising
background image

360

Query Command Library

FRQ: 0 0 0 1 0 30 0 0
TYP: 1009 1010 1011 1012 1013 1019 1020 1029 1033
FRQ: 0 0 0 1 30 0 0 0 31
MSG:
MSG:No User Message

Parameters

Status:

Setup:

Parameter

Description

Range

SYNC

RTCM status:
• *: Corrections from base received in rover

in due time.

• <space>: No corrections are received that

would be compatible with the” maximum
age of corrections” requirement.

*, <space>

VER

RTCM version

V2.3, V3

STID

Station ID received from the base

0-4095

STHE

Station health index received from the base 0-7 (RTCM2.3)

AGE

Age of last message received

0-999

TYPE

RTCM message being received or sent

1, 18/19, 20/21, 31,
1001, 1002, 1003,
1004, 1009, 1010,
1011, 1012

MSG

User message received in message type 16,
36 or 1029

90 characters max.

Parameter

Description

Range

MODE

RTCM Base/Rover mode:
• ROV: If the receiver is a rover.
• BAS: If the receiver is a base and the

selected differential data type is RT2 or
RT3.

ROV, BAS, OFF

PORT

Communication port:
• AUT, in rover mode, when the differential

reception mode is “AUT” (see
$PASHS,CPD,REM).

• One or two ports, in rover mode, when the

differential reception mode is “MAN” (see
$PASHS,CPD,REM)

• One or two ports, in base mode (see

$PASHS,BAS). Only if RT2 or RT3 is
used.

VER

RTCM version

V2.3, V3

STI

Station ID

0-4095

TYP

Type of RTCM message the receiver gener-
ates (base receiver only)

FRQ

Transmit rate of RTCM message, in seconds 0-1800

Advertising