Spectra Precision ProMark 800 Reference Manual User Manual

Page 149

Advertising
background image

137

Using Serial Commands

• Connect the USB key to the receiver.

• Wait until the USB logo appears on the receiver screen

and a message is prompted (

Upload Script?).

• Accept the request by pressing the Log button (you could

reject it by pressing the Scroll button). The receiver will
then start executing the script of commands. This is
indicated on the display screen where you can see the
number of commands to be run (on the right) and the rank
of the command being currently run (on the left). In the
example below, the receiver is running the 1st command
of the 18 ones it has to go through:

• When all the commands have been run, the receiver

comes back to the screen it was displaying before.

• Remove the USB key.

• You can now have a check on how the receiver ran each of

the commands: Connect the USB key to a computer and
edit the autoconfig.log file created on the USB key by the
receiver while executing the commands. Each correctly
executed command is followed by:

$PASHR,ACK*3D

USB Port

ProMark 800

Cable P/N 702104

USB Key

Advertising