Qzs: enabling/disabling qzss tracking, Command format, Relevant query command – Spectra Precision ProMark 800 Reference Manual User Manual

Page 230: Function

Advertising
background image

218

Set Command Library

Command Format

Syntax

$PASHS,PWR,PAR,f1,f2[*cc]

Parameters

Example

Setting the thresholds to respectively 7 and 9 V:

$PASHS,PWR,PAR,7,9*41

Relevant Query

Command

$PASHQ,PWR

QZS: Enabling/Disabling QZSS Tracking

Function

This command is used to enable or disable QZSS tracking.
The QZSS constellation tracking function is off by default.

Command Format

Syntax

$PASHS,QZS,s[*cc]

Parameters

Example

Enabling QZSS tracking:

$PASHS,QZS,ON

Relevant Query

Command

$PASHQ,QZS

$PASHQ,PAR

Parameter

Description

Range

Default

f1

Battery voltage threshold, in volts, trigger-
ing a low-battery alarm

6.7-8.4

6.8

f2

External power voltage threshold, in volts,
triggering a low-power alarm

9.0-28.0

9.1

*cc

Optional checksum

*00-*FF

-

Parameter

Description

Range

Default

s

Programmable pin ID:
• ON: QZSS satellites tracked and used
• OFF: QZSS satellites not tracked

ON or OFF OFF

*cc

Optional checksum

*00-*FF

Advertising