222

Set Command Library

Command Format

Syntax

$PASHS,RAW,PER,f[*cc]

Parameters

Example

Setting the data output rate to 2 seconds:

$PASHS,RAW,PER,2*44

Relevant Query

Command

$PASHQ,RAW

See also

$PASHS,RAW

$PASHS,RAW,ALL

$PASHS,POP

RCP,GBx: GLONASS Carrier Phase Biases for User-Defined
Receiver

Function

This set of two commands is used to define GLONASS carrier
phase biases for a given receiver. One command deals with
the GLONASS L1 band and the other with the GLONASS L2
band.

Command Format

Syntax

For the L1 band:

$PASHS,RCP,GB1,s1,f2,f3,f4,f5,f6,f7,f8,f9,f10,f11,f12,f13,f14,f15,f16,f17[*c
c]

For the L2 band:

$PASHS,RCP,GB2,s1,f2,f3,f4,f5,f6,f7,f8,f9,f10,f11,f12,f13,f14,f15,f16[*cc]

Parameter

Description

Range

Default

f

Output rate, in seconds.
Setting $PASHS,POP to “20”
is a prior condition to operat-
ing at 0.05 s (20 Hz).

0.05 s or 0.1-0.4 s with
[F] option activated.
0.5-0.9 s
1-999 s

1 s

*cc

Optional checksum

*00-*FF