Bas: differential data type, Response format, Example – Spectra Precision ProMark 800 Reference Manual User Manual

Page 281: See also, Function, Command format

Advertising
background image

269

Query Command Library

Parameters

Response Format

Syntax

$PASHR,ATO,c1,d2,f3,d4,7(s5,f6)*cc

Parameters

Example

Querying ATOM message parameters as currently set on port
A:

$PASHQ,ATO,A
$PASHR,ATO,A,7,001.00,7,MES,0.00,PVT,0.00,ATR,0.00,NAV,0.00,DAT,
0.00,EVT,0.00,RNX,0.00*07

See also

$PASHS,ATM

$PASHQ,ATM

BAS: Differential Data Type

Function

This command is used to list the message types generated
and sent by a base.

Command Format

Syntax

$PASHQ,BAS[*cc]

Parameter

Description

Range

c

Port ID for which you need to know the
ATOM message settings:
• A: Serial port
• C: Bluetooth port
• E: Modem
• M: Internal memory
• U: External memory (USB)

A, C, E, M, U

*cc

Optional checksum

*00-*FF

Parameter

Description

Range

c1

The port ID mentioned in the query com-
mand is replicated in this field.

A, C, E, M, U

d2

Baud rate code, 0 if not available

0-15

f3

PER setting

0-999.0

d4

Number of ATOM messages

7

s5

ATOM message type

MES, PVT, ATR,
NAV, DAT, EVT, RNX

f6

Output rate (0 if message disabled)

0-999.0

*cc

Checksum

*00-*FF

Advertising