135

Using Serial Commands

Interfacing the chosen program with the receiver is achieved
by establishing a connection through one of the computer’s
COM port (a serial data cable is then required), or using
Bluetooth if this device is available on the computer.

For more information on WinComm, see GNSS Solutions
Reference Manual
or WinComm On-Line Help.

When using HyperTerminal, perform the following settings
after creating a new connection (serial ports on Spectra
Precision receivers are usually set as follows: 19200 Bd, 8
data bits, 1 stop bit, no parity, no flow control), and before
typing your first command:

• In the HyperTerminal menu bar, select

File>Properties.

• Click on the

Settings tab.

• Click on the

ASCII Setup button.

• Enable the following two options:

Send line ends with line

feeds and Echo typed characters locally. This will
automatically complete all your command lines with
<cr><lf> characters and allow you to see in real time the
commands you are typing.

• Click

OK twice to close the Properties window.

From FAST Survey

From the FAST Survey menu, tap on the

Equip tab, then on

the

GPS Utilities button, and then on the Send Command

button. It is assumed that the communication with the
receiver has been established via Bluetooth or a serial cable.

Running a Single Command at a Time

• Tap your command directly in the combo box using FAST

Survey’s virtual keyboard. The keyboard appears
automatically when you tap inside the box.

• Tap

after you have typed the command line.

• Tap on the

Send button to send the command to the

receiver. The command line as well as the response line(s)
then appear at the bottom of the screen.