Rcp: receiver parameters, Relevant set command, Function command format – Spectra Precision ProMark 800 Reference Manual User Manual

Page 357

Advertising
background image

345

Query Command Library

Parameters

Relevant Set

Command

$PASHS,RAW

RCP: Receiver Parameters

Function

Command Format

Syntax

Parameter

Description

Range

PER

Output rate, in seconds

0.00-999.00

ELM

Elevation mask used in data recording &
data output

0-90

RAW

Raw data type

MPC, DPC, PBN,
SNV, SNG, SNW,
SAL, SAG, SAW,
ION, SBD

PRTA

Serial port

ON, OFF

PRTC

Bluetooth

ON, OFF

MEMM
MEMU

Labels for memories M (MEMM: internal
memory) and U (MEMU: USB key)

ON-OFF

BAUD

For serial port: Baud rate code
For other devices, “0” if not available, else
“1”

0-15 (see table
below)

Code

Baud Rate

Code

Baud Rate

0

300

7

38400

1

600

8

57600

2

1200

9

115200

3

2400

10

230400

4

4800

11

460800

5

9600

12

921600

6

19200

13

1428571

Advertising