Communications Menu • PC Set Up

Publication 1398-PM601A-EN-P — October 2000

MENUS

SHIFT+UP ARROW

Moves the display up one line.

SHIFT+DOWN ARROW

Moves the display down one line.

SHIFT+LEFT ARROW

Moves the display to the left.

SHIFT+RIGHT ARROW

Moves the display to the right.

PAGE UP

Moves the display up one page.

PAGE DOWN

Moves the display down one page.

CTRL+HOME

Moves to the beginning of the display.

CTRL+END

Moves to the end of the display.

PC Set Up

The serial communications settings for the PC are accessed from PC Set Up under the Communications
menu. The settings are stored in the file MASTER.INI which is a standard Windows INI file. After
changing any of the settings, choose the OK button to change the settings for the current session only.
To make the changes permanent, choose the Save Changes button. The file can also be edited with any
editor, but should not be edited while IQ Master is running. To change the serial settings for the ULTRA
Plus or IQ, select Serial under the Parameters menu.

Baud Rate

Baud Rate can be set to 1200, 2400, 4800, 9600 (default), or 19200.

Communications Port

Com Port selects the communications port. If a Com Port is already open under another Windows appli-
cation, it must be closed before it can be used in IQ Master.

CR (Carriage Return) Translation

CR Translation can add a linefeed (LF) to a carriage return (CR) or just pass the CR on without adding
a linefeed. This applies to Terminal mode only.

Data Bits

Data Bits can set the number of data bits to 7 or 8. The default number of data bits for the ULTRA Plus
or IQ is 8.

Stop Bits

Stop Bits can set the number of stop bits to 1 or 2. The ULTRA Plus or IQ is always fixed at 1 stop bit.

Flow Control

Flow Control determines what type of handshake to use–XON/XOFF for software handshake or RTS/
CTS for hardware handshake. The ULTRA Plus or IQ only uses software handshake and does not sup-
port hardware handshake.

Parity

Parity can be set to none (default), even, or odd.

Note: To transfer a program, use Save Program to IQ or Open IQ Program from the File menu

Note: The position and size of the Terminal window is stored every time you close Terminal. IQ
Master remembers where you last positioned the window and displays it in the same place the next
time you open the Terminal window.