Gains – Rockwell Automation 1398-PDM-xxx IQ Master Version 3.2.4 for IA-2000 and IQ-5000 Positioning Drive Modules, IQ-55 User Manual

Page 324

Advertising
background image

302

Variables and Flags Assignment and Request Commands • Gains

Publication 1398-PM601A-EN-P — October 2000

HOST

M

O

D

E

Gains

Command

Description

Flag/

Variable

Read/
Write

Personality

Module

FGAIN

Acceleration feedforward gain

V

R/W

Y

#

FILTEN

TRUE to enable the velocity loop filter

F

R/W

Y

#

FILTER or FIL

Velocity loop filter value

V

R/W

Y

#

IGAIN

Integral gain for the velocity loop

V

R/W

Y

#

IZONE

Region where KI has effect

V

R/W

Y

#

KFF

Velocity feedforward gain

V

R/W

Y

#

KI

Integral gain for the position loop

V

R/W

Y

#

KP

Proportional gain for the position loop

V

R/W

Y

#

KPZ

Proportional gain used within the PZONE

V

R/W

Y

#

MXFGAIN

Maximum FGAIN

V

R

Y

MXFILTER

Maximum FILTER

V

R

Y

MXIGAIN

Maximum IGAIN

V

R

Y

MXKFF

Maximum KFF

V

R

Y

MXKI

Maximum KI

V

R

Y

MXKP

Maximum KP

V

R

Y

MXPGAIN

Maximum PGAIN

V

R

Y

PGAIN

Proportional gain for the velocity loop

V

R/W

Y

#

PZONE

Region where KPZ is used instead of KP

V

R/W

Y

#