Variables and Flags Assignment and Request Commands • Homing

303

Publication 1398-PM601A-EN-P — October 2000

HOST M

O

DE

Homing

These variables and flags are used in conjunction with the standard Home Program. Refer to Appendix
A, System Programs, for more detailed information about the home program and the uses of these vari-
ables.

Command

Description

Flag/

Variable

Read/
Write

Personality

Module

DHINP

If the Define Home input is assigned, the single bit set
in the word corresponds to the input assigned to the
function. A value of zero indicates that the function is
not assigned. Care must be taken to avoid assigning
multiple functions to the same input.

word

R/W

Y

HACTIVE

TRUE for active closed home switch.

F

R/W

Y

HOFFS

Home offset.

V

R/W

Y

#

HRINP

If the HRESET input is assigned, the single bit set in
the word corresponds to the input assigned to the func-
tion. A value of zero indicates that the function is not
assigned. Care must be taken to avoid assigning multi-
ple functions to the same input.

word

R/W

Y

HSEQEN

TRUE to enable Home Sequence Complete output.

F

R/W

Y

HVEL or HV

Home velocity.

V

R/W

Y

#

INDEX

TRUE for encoder index positioning during home.

F

R/W

Y