Language Reference • Reference

217

Publication 1398-PM601A-EN-P — October 2000

WORDS

HVEL

Home Velocity

Home

Purpose

Set the velocity used by the Home program.

Syntax

HVEL = value
variable =
HVEL

value

The velocity in user units per user Timebase. User units are
defined by the SCALE parameter. Value can be a constant, a
nonvolatile variable Gn, a volatile variable Vn, or a system
variable.

variable

The variable may be a nonvolatile variable Gn, a volatile vari-
able Vn, or a system variable.

Remarks

Changes made to this variable by a program are only in effect while the program is
running. When the program ends it will return to the value stored in the Personality
Module. If no change is made to this variable by the program, the value in the Person-
ality Module is used. The value in the Personality Module is set in the Parameter
menu, Velocity/Accel dialog box.

See Also

JVEL, VEL, Appendix A, System Programs

Example

HVEL = 10

G4 = HVEL

Im

Input

Inputs

Purpose

Read or test a digital input.

Syntax

variable = Im

m

The number of the input: m = 1, 2,

,16. If the controller is

equipped with an I/O Expansion card or a Memory and I/O
Expansion card, m = 1, 2,

,48.

Remarks

See Also

Om

Example

F1 = I1

IF I1 = ON

WAIT I1 = ON