Flow chart, Ultra plus or iq parameter settings, Appendixes flow chart ultra plus – Rockwell Automation 1398-PDM-xxx IQ Master Version 3.2.4 for IA-2000 and IQ-5000 Positioning Drive Modules, IQ-55 User Manual

Page 384: Iq parameter settings

Advertising
background image

362

Application Examples • SmartBelt Application

Publication 1398-PM601A-EN-P — October 2000

APPENDIXES

Flow Chart

ULTRA Plus

or

IQ Parameter Settings

CONFIGSet ULTRA Plus or IQ configuration to accept encoder 2 input for electronic gearing

SCALEnumber of encoder counts per unit distance on driven belt

SCALE2number of encoder counts per unit distance of belt

ACCELallowable acceleration rate without slippage of product

VELmotor top speed during correction at machine top speed

TITLE "SBELT"

;Version 3.00 2/29/96

PGMTYPE = MAINPGM

;

ASSIGN OFFSET V1

;OFFSET is desired distance: flight to product

ASSIGN OFFSET2 V2

;

OFFSET = 1.2345

;Set OFFSET in user units (inches, cm, etc.)

OFFSET2 = UTOC1 OFFSET

;Convert OFFSET to encoder counts

; based on SCALE parameter setting

INT1 CONT

;Enable interrupts to capture positions

INT2 CONT

;Input 11 is INT1, Input 12 is INT2

GEAR = 1.00

;Initialize gear ratio

GEAREN ON

;Start tracking the master encoder

WAIT I11 ON

;Wait for first flight

;

MAIN:

;Main loop of program

CALCULATE CORRECTION DISTANCE

START

INITIALIZE VARIABLES

ACTIVATE INTERRUPTS

ACTIVATE ELECTRONIC GEARING

WAIT FOR A FLIGHT

PRODUCT?

PERFORM CORRECTION MOVE

MAKE SURE PRODUCT IS OFF SENSOR

NO

YES