TUTORIAL

Gain

(cont.)

PGAIN

Proportional gain for the velocity loop

V

R/W

Y

PZONE

Region where KPZ is used instead of
KP

V

R/W

Y

Home

ATHOME

At home used in Absolute mode only

F

R

N

HOFFS

Home offset

V

R/W

Y

HOMECMD

Runs Home program when set

F

R/W

N

HSEQCPL

Home sequence complete

F

R

N

HSWEN

Set if Home Switch input enabled

F

R

Y

HSWSTAT

Current status of Home Switch input
(regardless if active open or closed)

F

R

N

HVEL

Home velocity

V

R/W

Y

Input and

ADC1

Analog input 1 in volts

V

R

N

Outputs

ADC2

Analog input 2 in volts

V

R

N

ADC3

Analog input 3 in volts

V

R

N

ADC4

Analog input 4 in volts

V

R

N

ADC5

Analog input 5 in volts

V

R

N

DAC1

Analog output 1 in volts

V

W

N

Interrupt

FI1

Interrupt 1 flag

F

R/W

N

FI2

Interrupt 2 flag

F

R/W

N

FIDX1

Encoder 1 index interrupt flag

F

R/W

N

FIDX2

Encoder 2 index interrupt flag

F

R/W

N

I1P1

Position 1 latched by interrupt 1 in user
units

V

R

N

I1P2

Position 2 latched by interrupt 1 in user
units

V

R

N

I2P1

Position 1 latched by interrupt 2 in user
units

V

R

N

I2P2

Position 2 latched by interrupt 2 in user
units

V

R

N

IDX1

Enable flag for Encoder 1 index inter-
rupt

F

R/W

N

IDX2

Enable flag for Encoder 2 index inter-
rupt

F

R/W

N

IX1P1

Position 1 latched by Encoder 1 index
interrupt

V

R

N

IX1P2

Position 2 latched by Encoder 1 index
interrupt

V

R

N

IX2P1

Position 1 latched by Encoder 2 index
interrupt

V

R

N

Type

Name Description

Flag/

Variable

Read/
Write

Personality

Module