Rockwell Automation 1398-PDM-xxx IQ Master Version 3.2.4 for IA-2000 and IQ-5000 Positioning Drive Modules, IQ-55 User Manual

Page 252

Advertising
background image

230

Language Reference • Reference

Publication 1398-PM601A-EN-P — October 2000

WORDS

KFF

Velocity feedforward Gain

Gain

Purpose

Set the velocity feedforward gain to a new value. Velocity feedforward gain may be
changed at any time in the program.

Syntax

KFF = value
variable =
KFF

value

The value is entered in percent. The value can be a constant, a
nonvolatile variable Gn, a volatile variable Vn, or a system
variable. The range of this value is 0 to 200%.

variable

The variable may be a nonvolatile variable Gn, a volatile vari-
able Vn, or a system variable.

Remarks

Changes made to this variable by a program are only in effect while the program is
running. When the program ends it will return to the value stored in the Personality
Module. If no change is made to this variable by the program, the value in the Person-
ality Module is used. The value in the Personality Module is set in the Parameter
menu, Gains/Limits dialog box.

See Also

KP, KPZ, PZONE, KI, IZONE

Example

KFF = 75

KFF = V8

V7 = KFF

KI

Integral Gain, Position Regulator

Gain

Purpose

Set the integral gain to a new value. The position regulator integral gain may be
changed at any time in the program. The integral gain is active when the position error
is less than IZONE (regardless of commanded velocity). If IZONE is set to zero, inte-
gral gain is not active.

Syntax

KI = value
variable =
KI

value

The value can be a constant, a nonvolatile variable Gn, a vola-
tile variable Vn, or a system variable.

variable

The variable can be a nonvolatile variable Gn, a volatile vari-
able Vn, or a system variable.

Remarks

Changes made to this variable by a program are only in effect while the program is
running. When the program ends it will return to the value stored in the Personality
Module. If no change is made to this variable by the program, the value in the Person-
ality Module is used. The value in the Personality Module is set in the Parameter
menu, Gains/Limits dialog box.

See Also

IZONE, KP, KPZ, PZONE, KFF

Example

KI = 1.5

KI = G3

V4 = KI

Advertising