Motion • Feedrate

Publication 1398-PM601A-EN-P — October 2000

TUTORIAL

plished by executing a MOVD. The MOVD command will cause the motor to move by the specified
distance relative to the encoder while following the encoder.

Feedrate

Feedrate (FDR) scales the timebase for motion. With the feedrate set at 100%, all velocities and
DWELLs are at the programmed rates. Feedrate can be set to less than 100% to slow down a process, or
above 100% to speed it up. Feedrate can be changed at any time in the program and is entered as a per-
centage with a range of 0 to 200.

Feedrate will affect MOVD, MOVP, MOVV, DIF, DV, and DWELL instructions. The velocity, acceler-
ation, and time in these functions will be scaled by the FDR percentage.

For example, if the velocity is set to 3,000 RPM and the FDR is set to 50, any motion will have a veloc-
ity that is 50% of 3,000 RPM or 1,500 RPM (3000 * 0.5 = 1500). A DWELL time is also scaled by
FDR. A DWELL of 10 seconds would be scaled to 20 seconds (10 / 0.50 = 20). A feedrate can also be
set with the analog input. This is accomplished by assigning the analog input to FEEDRATE in the
Parameter Inputs dialog box.

Changes made to this variable by a program are only in effect while the program is running. When the
program ends, feedrate will return to the value stored in the Personality Module. If no change is made to
this variable by the program, the value in the Personality Module is used. The value in the Personality
Module is set in the Parameter menu.

Dwell Statement

The DWELL statement will cause the program to stop for the specified amount of time. The time will
be scaled by the feedrate system variable discussed above.

Delay Statement

The DELAY statement will cause the program to stop for the specified amount of time. The time will
NOT be scaled by the feedrate system variable.

Motion Instruction Summary

The following is a summary of the commands that can be used to generate motion. Refer to Part 5

Language Reference for more detailed information.

Name

Description

D = dist, V = vel [, S]

Define one linear segment of a move

DELAY = time

Delay for a specified time (not affected by feedrate)

DIF = dist, cond, JUMP label

Move until the distance is reached or the condition occurs

DWELL = time

Dwell for the specified time (affected by feedrate)

FDR

Adjust the feedrate for motion from 0% to 200%

GEAR = value

Set the gear ratio

GEAREN = ON/OFF

Enable/Disable gearing