Rockwell Automation 1398-PDM-xxx IQ Master Version 3.2.4 for IA-2000 and IQ-5000 Positioning Drive Modules, IQ-55 User Manual
Page 202
180
Language Reference • Reference
Publication 1398-PM601A-EN-P — October 2000
WORDS
ALL
All Outputs
Outputs
Purpose
Turn all outputs ON or OFF. Assigned outputs such as Program Running, Error, At
Home, Home Sequence Complete, or In-Position are not affected unless disabled from
the Parameters menu, Outputs dialog box.
Syntax
ALL ON/OFF
ON
Turn all outputs ON. Outputs are current sinking type. ON turns
on the transistor and pulls the output to 24V common.
OFF
Turn all outputs OFF. Outputs are current sinking type. OFF
turns off the transistor and leaves the outputs floating. There is
no internal pull-up.
Remarks
Refer to the appropriate ULTRA Plus or IQ-Series Installation Manual (1398-5.1, Part
Number 0013-1027-004 or Part Number 0013-1022-004) for electrical specifications.
See Also
On = ON/OFF/Fn
Example
ALL ON
ALL OFF