Flow chart, Appendixes flow chart – Rockwell Automation 1398-PDM-xxx IQ Master Version 3.2.4 for IA-2000 and IQ-5000 Positioning Drive Modules, IQ-55 User Manual

Page 422

Advertising
background image

400

Application Examples • Lane Diverter

Publication 1398-PM601A-EN-P — October 2000

APPENDIXES

Flow Chart

TITLE "lane_dv2"

;Version 3.00 2/29/96

PGMTYPE = MAINPGM

;

G Variable Assignments

;3 sizes of packages: 0-range1, range1-range2, range2 or

; larger

ASSIGN Range1G1

ASSIGN Range2G2

ASSIGN Gate_pos1

G3

;the first gate position

ASSIGN Gate_pos2

G4

;the second gate position

ASSIGN Gate_pos3

G5

;the third gate position

ASSIGN Min_vel

G6

;the minimum web velocity allowed (in case belt stops)

ASSIGN Deb_dist

G7

;debounce distance: distance package must go before

; looking for a trailing edge

ASSIGN Gate_length G8

;the distance from in_sense to the back of the gate

;

V Variable Assignments

ASSIGN Deb_pos

V1

;position that debounce will be done

ASSIGN Pkg_length1 V2

;the length of the package being sorted

ASSIGN Pkg_length2 V3

;the length of the package being measured

ASSIGN Eon1

V4

;leading edge web position for the package being

; sorted

ASSIGN Eon2

V5

;leading edge web position for the package being

; measured

ASSIGN Target

V6

;the target gate position

Start

Turn on Package Scan
Turn on Feedrate Override Scan

Wait for all exit sensors to clear

Wait for package to be sensed

Get package parameters
reset Package Scan

Set target according to package size

Calculate velocity using vel2

Calculate velocity using minimum vel2

Wait for package to exit the gate

Vel2 < minimum velocity

?

yes

no

Move to target with calculated velocity