Language Reference • Reference

Publication 1398-PM601A-EN-P — October 2000

WORDS

Remarks

The present value of OTMON can also be read and used in a conditional statement.

See Also

PRINT

Example

;Monitor POSN on the Operator Terminal

OTMON = 2

;If POSN is being monitored, stop monitoring POSN and clear the top line

;of the Operator Terminal

IF(OTMON = 2)OTMON = 0

OVERSPEED

Overspeed Threshold

System

Purpose

Peak velocity trip point in user units per timebase. If the velocity exceeds this trip
point, a fault is reported.

Syntax

OVERSPEED = variable
variable
= OVERSPEED

variable

Variable can be a constant, a nonvolatile variable Gn, a volatile
variable Vn, or another system variable.

Remarks

Changes made to this variable by a program are only in effect while the program is
running. When the program ends it will return to the value stored in the Personality
Module. If no change is made to this variable by the program, the value in the Person-
ality Module is used. The value in the Personality Module is set in the Parameter
menu, Velocity/Accel dialog box

See Also

VEL

Example

V4 = OVERSPEED

OVERSPEED=3500