Language Reference • Reference

183

Publication 1398-PM601A-EN-P — October 2000

WORDS

BCD Om, n
BIN Om, n

Output, Binary Coded Decimal

Output, Binary

Outputs

Purpose

Set a group of outputs, in either binary (BIN) or binary coded decimal (BCD) format,
to the value of a variable.

Syntax

BCD Om, n = value
BIN Om, n = value

m

The output specified by m is set to the least significant bit of
variable.

n

n is the number of outputs included in the group.

value

The value can be a constant, a nonvolatile variable Gn, a vola-
tile variable Vn or a system variable.

Remarks

If the value is greater than n bits, the least significant n bits are output.

See Also

Example

BCD 03, 4 = V1

;Set outputs 3, 4, 5, and 6

BCD 03, 2 = 2

;Set output 3 OFF and output 4 ON

BIN 04, 3 = G7

;Set outputs 4, 5, and 6

BCD variable = Im, n
BIN variable = Im, n

Input, Binary Coded Decimal

Input, Binary

Inputs

Purpose

Read a group of inputs in either binary (BIN) or binary coded decimal (BCD) for-
mat into a variable.

Syntax

BCD variable = Im, n
BIN variable = Im, n

m

The input specified by m is the least significant bit of
the group.

n

n is the number of inputs included in the group.

variable

The variable may be a nonvolatile variable Gn, a vol-
atile variable Vn or a system variable.

Remarks

If the BCD instruction is used and the value is out of range, a BCD input out of
range error will be generated.

See Also

Im

Example

BCD V3 = I9, 4

;Read BCD value of inputs 9, 10, 11, and

12

;into V3

BIN V11 = I13, 2

;Read binary value of inputs 13 and 14

;into V11