72

Diagnostics Menu • Monitor Variables

Publication 1398-PM601A-EN-P — October 2000

MENUS

Diagnostics Menu

The Diagnostics menu contains several submenus for various diagnostic tests. The Diagnostics mode is
intended for troubleshooting while the ULTRA Plus or IQ is disabled and no program is running. The
Encoder test checks both Encoder 1 and Encoder 2. The DAC1 Output test exercises the Digital to Ana-
log Converter (DAC1) output. The Programmable Monitor Output test exercises the Programmable
Monitor Output. The Digital Outputs test allows digital outputs to be forced ON or OFF to test the out-
puts and system wiring. The Operator Terminal test verifies communication between the ULTRA Plus
or IQ and the Operator Terminal. The Nonvolatile Memory Test does a nondestructive test of the
ULTRA Plus or IQ nonvolatile RAM (NVRAM). Fault History shows the last 46 faults and the running
time when the fault occurred. Version shows the current version of the firmware in the ULTRA Plus or
IQ.

Note: To check the Analog to Digital Converter (ADC), select Monitor Variable from the Monitor
menu. To check the Digital Inputs, select Inputs/Outputs from the Monitor menu